<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ver Pangonilo - Filipino Engineer &#187; Arc-Flash</title>
	<atom:link href="http://s.pangonilo.com/index.php/tag/arc-flash/feed" rel="self" type="application/rss+xml" />
	<link>http://s.pangonilo.com</link>
	<description>Professional Electrical Engineer</description>
	<lastBuildDate>Tue, 07 Feb 2012 18:33:36 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>Arc-flash Hazard Protection &#8211; IEC Standard</title>
		<link>http://s.pangonilo.com/index.php/2009/11/arc-flash-hazard-protection-iec-standard.html</link>
		<comments>http://s.pangonilo.com/index.php/2009/11/arc-flash-hazard-protection-iec-standard.html#comments</comments>
		<pubDate>Mon, 09 Nov 2009 02:50:32 +0000</pubDate>
		<dc:creator>Ver</dc:creator>
				<category><![CDATA[Design]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[Standards]]></category>
		<category><![CDATA[Arc-Flash]]></category>
		<category><![CDATA[Protection]]></category>

		<guid isPermaLink="false">http://s.pangonilo.com/?p=951</guid>
		<description><![CDATA[IEEE has dedicated standards in Arc-flash hazard mitigation and protection (IEEE 1584 &#38; NFPA 70E) while IEC has integrated its arc-flash protection into the IEC 62271-200, High-voltage switchgear and controlgear ÃƒÂ¢Ã¢â€šÂ¬Ã¢â‚¬Å“ Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV. IEC 62271-200 recommends metal-enclosed [...]]]></description>
		<wfw:commentRss>http://s.pangonilo.com/index.php/2009/11/arc-flash-hazard-protection-iec-standard.html/feed</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Calculating Flash Protection Boundary Distances</title>
		<link>http://s.pangonilo.com/index.php/2009/01/calculating-flash-protection-boundary-distances.html</link>
		<comments>http://s.pangonilo.com/index.php/2009/01/calculating-flash-protection-boundary-distances.html#comments</comments>
		<pubDate>Tue, 06 Jan 2009 12:37:33 +0000</pubDate>
		<dc:creator>Ver</dc:creator>
				<category><![CDATA[Safety]]></category>
		<category><![CDATA[Arc-Flash]]></category>
		<category><![CDATA[Hazards]]></category>

		<guid isPermaLink="false">http://s.pangonilo.com/?p=91</guid>
		<description><![CDATA[In NFPA 70E, the short-circuit symmetrical ampacity from a bolted 3-phase fault at the transformer terminals is calculated with the following formula: Isc = {[MVA Base ÃƒÆ’Ã¢â‚¬â€ 106] ÃƒÆ’Ã‚Â· [1.732 ÃƒÆ’Ã¢â‚¬â€ V]} ÃƒÆ’Ã¢â‚¬â€ {100 ÃƒÆ’Ã‚Â· %Z} where Isc = Amperes, V = Volts, %Z = transformer MVA. A typical value for the maximum power (in [...]]]></description>
		<wfw:commentRss>http://s.pangonilo.com/index.php/2009/01/calculating-flash-protection-boundary-distances.html/feed</wfw:commentRss>